Software as a Medical Device is software intended for one or more medical purposes that performs those purposes without being part of a hardware medical device. In the United States, FDA oversight depends on the software function, its intended use, and applicable statutory and regulatory criteria. IEC 62304 provides a lifecycle framework for medical device software development and maintenance, covering planning, requirements, design, implementation, verification, testing, risk management, configuration management, and maintenance. Buyers need a development partner who understands both the applicable regulatory context for their specific product and the engineering processes needed to produce safe, validated, documented software.
What does a developer need to know to build FDA-regulated SaMD? A developer working on SaMD needs to understand intended use and device classification, applicable FDA submission requirements, software documentation expectations, IEC 62304 lifecycle processes, software safety classification, ISO 14971 risk management, ISO 13485 quality management system requirements, verification and validation, cybersecurity practices, and configuration and change management. General healthcare software experience is not the same as regulated medical device software development experience.
Software as a Medical Device is software intended for one or more medical purposes that performs those purposes without being part of a hardware medical device. This definition comes from the International Medical Device Regulators Forum (IMDRF) and is referenced by FDA in its approach to device software functions.
The key factor in determining whether software qualifies as SaMD is its intended purpose, not where it is used or who uses it. Software deployed in a clinical environment does not automatically become SaMD. What matters is whether it is intended to perform a medical function, such as detecting, diagnosing, treating, monitoring, or predicting a medical condition.
Examples of software that may qualify as SaMD, depending on intended use and applicable criteria:
The fact that software is accurate, clinically useful, or medically informed does not by itself determine whether it qualifies as SaMD. A nutrition tracking application, a symptom diary, or a hospital scheduling tool may be used in healthcare settings without meeting the criteria for a medical device. The intended medical purpose is what determines regulatory status, and that determination must be made in the context of the actual product, its labeling, and the applicable regulatory framework.
Software as a Medical Device and software embedded in or controlling a hardware medical device are related categories that carry different development responsibilities, risk profiles, and regulatory considerations. Understanding the distinction matters before a development team is selected or a development approach is planned.
Software as a Medical Device (SaMD): Standalone software that performs a medical purpose without being part of a hardware medical device. Runs on general computing platforms such as a server, cloud environment, tablet, or smartphone. Example: a standalone radiology AI application that runs on a radiologist's workstation.
Software in a Medical Device (SiMD): Software that is part of a hardware medical device or is necessary for it to work as intended. The software is integrated with the device and subject to the full device regulatory framework. Example: software embedded in an infusion pump that controls drug delivery rates.
Software that controls a medical device: Software whose primary purpose is to operate or control a hardware device. Example: firmware embedded in an imaging machine that manages image acquisition.
General healthcare software: Software that does not meet the applicable medical device definition. Example: hospital appointment scheduling systems, general wellness trackers without medical purpose claims, administrative workflow tools.
The practical implication for buyers: a development company experienced in building general healthcare software, patient portals, or health information systems is not necessarily experienced in building software that is part of a medical device or that qualifies as SaMD. Each category carries different documentation, lifecycle, risk management, and regulatory requirements, and the development team needs to understand which category their product falls into before work begins.
TechRadiant's directory of medical device software development companies provides a resource for evaluating vendors with regulated medical device software experience before shortlisting.
No. The fact that an application handles health-related data or is used by clinicians does not make it a medical device. FDA's approach to device software functions recognizes that software falls across a broad spectrum, and not every software function falls within device oversight.
FDA has identified categories of software functions that it generally does not intend to regulate as medical devices. These include software intended for general wellness, administrative healthcare functions, and certain types of clinical communication tools that do not analyze, interpret, or recommend based on patient-specific data for medical purposes.
Clinical decision support software (CDS) occupies a particularly complex position. FDA's January 2026 Clinical Decision Support Software guidance provides the current framework for distinguishing CDS software that qualifies as a device function from CDS software that is intended to remain outside device regulation. Under this framework, non-device CDS software generally must meet several criteria, including being intended to support or provide recommendations to a healthcare professional who can independently review the basis for the recommendation. CDS that meets the criteria for non-device CDS does not require FDA premarket review as a medical device, but the determination depends on the actual software function, its intended use, and how it is presented to users.
AI-powered medical software requires the same intended-use analysis as any other software function. An AI tool that generates health insights for general wellness purposes is treated differently from one that analyzes medical images for diagnostic purposes. The underlying technology, however sophisticated, does not by itself determine regulatory status. What the software is intended to do, for which users, and in which clinical context is what matters.
Determination is product-specific. Whether a specific software product or function qualifies as a medical device under FDA's framework depends on the actual product, its intended use, its labeling and marketing, and applicable statutory and regulatory criteria. This requires product-specific regulatory analysis, not a general category assessment.
FDA regulates medical devices under the Federal Food, Drug, and Cosmetic Act (FD&C Act). A medical device includes an instrument, apparatus, machine, contrivance, implant, in vitro reagent, or other similar or related article intended for a medical purpose. Software that meets this definition is a medical device.
FDA's regulatory approach to device software functions is risk-based. It considers the intended use and indications for use, the significance of the information the software provides, the degree to which a healthcare professional can independently review the basis for a software output, and the seriousness of harm that could result from an incorrect output or software failure.
Device classification determines the applicable regulatory pathway. FDA classifies medical devices into three classes, with higher-risk devices subject to more rigorous premarket review:
Not every SaMD product requires a 510(k) submission or PMA. Device classification, applicable exemptions, and the specific product's characteristics determine which pathway applies. Some Class I SaMD products may be exempt from premarket notification requirements. Regulatory strategy should be developed with qualified regulatory affairs expertise, as the determination is product-specific and consequential.
Postmarket responsibilities apply to medical device manufacturers regardless of the premarket pathway taken. These include complaint handling, medical device reporting, correction and removal, and quality management system maintenance.
The software documentation relevant to an FDA premarket submission depends on the device type, its risk level, the applicable regulatory pathway, and the submission type. FDA's June 2023 Content of Premarket Submissions for Device Software Functions guidance describes the documentation that may be relevant for software-containing devices submitted through 510(k), De Novo, PMA, or other applicable pathways.
Documentation that may be relevant, depending on the product and applicable requirements:
The specific documentation required varies by product and submission type. A development partner should understand what documentation they are expected to produce and how it supports both the manufacturer's quality management system and any applicable premarket submission.
IEC 62304 is an international standard that specifies lifecycle processes for medical device software development and maintenance. It was first published in 2006, with Amendment 1 published in 2015, and FDA has included it in its recognized consensus standards database. When a manufacturer declares conformity to a recognized standard in a premarket submission, FDA may accept that declaration as sufficient evidence for the standard's scope, reducing the review burden for those elements.
IEC 62304 defines a structured set of processes that apply throughout the software lifecycle. These include:
A developer who claims familiarity with IEC 62304 should be able to describe concretely how they apply each of these processes, what documentation they produce, and how their processes connect to the manufacturer's quality management system and risk management activities.
IEC 62304 defines three software safety classes that determine which development processes and verification activities are required. Classification is based on the potential consequences of a software failure and must be assessed in the context of the medical device system, including the hardware environment, applicable risk controls, and the harm that could result from a software failure.
Classification is not a simple lookup exercise. It requires analysis of the medical device system, the software's role within it, the potential hazards associated with software failure, and the risk controls in place. A software system can contain software items of different safety classes, and the classification of each item must be documented and justified.
An experienced development partner will not simply assign a safety class without documented analysis. Buyers should ask how a proposed team determines and documents software safety classification, and what that classification means for their specific development process and verification activities.
No. IEC 62304 focuses specifically on software lifecycle processes. It does not independently cover all requirements for a complete medical device development program, and buyers should understand what complementary standards and regulatory requirements apply alongside it.
IEC 62304 works in conjunction with several other standards and frameworks:
Important distinction: Conformance to IEC 62304 alone does not establish compliance with FDA regulatory requirements, does not substitute for a premarket submission, and does not independently cover all aspects of system-level validation, clinical evaluation, or final device release. Conformance to IEC 62304 is one component of a compliant medical device software development program, not a substitute for the full regulatory framework.
IEC 62304 is a standard, not a statute or regulation. FDA has included IEC 62304 in its recognized consensus standards database, which means FDA accepts declarations of conformity to recognized standards as evidence in premarket submissions. This is not the same as making the standard a legal requirement.
What this means in practice:
The distinction matters for buyers because a development company claiming to be "IEC 62304 compliant" or "FDA compliant" may mean different things. The question is not whether the company asserts compliance, but whether it can demonstrate the specific processes, documentation, and evidence that the standard and applicable regulatory pathway require.
FDA regulates medical devices and their manufacturers. IEC 62304 provides a recognized lifecycle framework for the software development process. The two are related but serve different functions, and an experienced development partner understands how to translate both into practical engineering work.
| Area | FDA Regulatory Context | IEC 62304 Contribution |
|---|---|---|
| Product classification | Determines the applicable device regulatory framework and submission pathway | Does not independently determine FDA classification or applicable pathway |
| Intended use | Determines whether software qualifies as a regulated device function | Supports development of software against clearly defined, documented requirements |
| Software development | Expects appropriate design and development controls within the QMS | Provides structured lifecycle processes from planning through release |
| Risk management | Considers device and patient safety risks throughout the product lifecycle | Integrates software risk management activities into lifecycle processes, in coordination with ISO 14971 |
| Verification and validation | Expects appropriate testing evidence depending on product and applicable pathway | Defines software verification and testing activities by safety class |
| Documentation | May require software documentation in premarket submissions and quality records | Structures software lifecycle records and documentation requirements |
| Maintenance | Postmarket quality and reporting responsibilities apply as relevant | Provides software maintenance processes for handling changes, defects, and improvements |
| Cybersecurity | February 2026 guidance addresses expectations for applicable cyber devices | IEC 62304 alone does not fully cover cybersecurity; supplemented by other standards and practices |
An experienced development partner translates regulatory expectations into engineering decisions throughout the project, not only at the documentation phase. Requirements traceability, risk-based testing, change controls, and release decisions should all reflect both the applicable regulatory context and the IEC 62304 lifecycle processes.
ISO 13485:2016 specifies quality management system requirements for organizations involved in the design, production, installation, and servicing of medical devices. For medical device software development, the quality management system provides the framework within which IEC 62304 lifecycle processes operate.
Key quality management system elements that apply to software development include:
An important distinction for buyers outsourcing development: the medical device manufacturer retains its quality management system responsibilities regardless of which development activities are performed by an external partner. A contracted development company may operate within the manufacturer's quality system as a supplier, contribute to the manufacturer's design and development records, or maintain its own quality management system aligned with the manufacturer's requirements. The allocation of responsibilities should be documented in the development agreement and clearly understood before work begins.
The FDA's Quality Management System Regulation (QMSR) became effective February 2, 2026, and aligns with ISO 13485:2016 more closely than the previous Quality System Regulation (QSR). Manufacturers who have been operating under the previous QSR and development partners working with US-regulated medical device manufacturers should understand the QMSR's requirements and how they affect design and development controls, supplier management, and documentation requirements.
ISO 14971:2019 specifies the requirements for a risk management process for medical devices. For software-containing medical devices and SaMD, risk management is not a final documentation step. It runs throughout the software lifecycle and influences architecture decisions, requirements, testing priorities, and release criteria.
The ISO 14971 risk management process includes:
For software, risk management should influence architecture from the outset. A diagnostic software function whose failure could affect a clinical decision requires different architectural safeguards, testing rigor, and release criteria than a utility function with no direct patient impact. A development partner who treats risk management as a documentation exercise performed after development is complete is not applying risk management in the way ISO 14971 or IEC 62304 intend.
Verification and validation are distinct activities in the medical device software context, and the distinction matters.
Software verification is the confirmation, through objective evidence, that the outputs of a software development phase meet the requirements for that phase. It answers the question: did we build the software correctly? Verification activities include unit testing, integration testing, code review, and static analysis.
Software validation is the confirmation, through objective evidence, that software that is to be used as or in a medical device fulfills its intended use and user needs. It answers the question: did we build the right software? Validation connects the software to its intended medical purpose and clinical context.
These are different from clinical validation or clinical evaluation, which address whether the device performs its medical purpose safely and effectively in the intended clinical population.
Testing activities for medical device software may include:
Test traceability connects requirements, identified risks, test cases, and test results. A traceability matrix shows that every requirement has been tested, that risk controls have been verified, and that the testing evidence supports the release decision. This traceability is typically part of the software documentation package relevant to a premarket submission.
Hypothetical example: A diagnostic support software function analyzes a patient's lab results against reference ranges and generates an alert for a clinician when a value suggests a potential condition. The requirement that the alert fires when a lab value exceeds the threshold is a testable requirement. The risk that the alert fails to fire when it should, possibly delaying clinical intervention, is a software-related hazard that should be identified in the risk analysis. A test case that specifically tests the alert trigger at boundary values, documents the expected result, and records the actual result is the evidence that connects that requirement and that risk to the testing process. If the software is modified to change the alert threshold, regression testing should confirm that the alert behavior remains correct.
AI-enabled medical device software introduces additional considerations that go beyond the standard IEC 62304 lifecycle processes. FDA has been developing its regulatory framework for AI in medical devices over several years, and buyers developing AI-powered SaMD should understand the current state of that framework.
FDA's January 2025 draft guidance on AI-enabled device software functions described an approach to regulating the marketing, labeling, transparency, and performance monitoring of AI-enabled devices. FDA's August 2025 final guidance on Predetermined Change Control Plans (PCCPs) provided a pathway for manufacturers to describe anticipated modifications to AI models in advance, allowing changes within the PCCP scope to proceed without a new premarket submission. Buyers should check FDA's current guidance documents for any subsequent updates, as this area continues to develop.
Key considerations for AI-powered SaMD development:
AI regulation is product-specific: Not all AI-powered medical software follows the same regulatory pathway. Whether an AI-enabled software function is a medical device, which classification applies, and whether a PCCP is relevant are product-specific determinations that require regulatory analysis. FDA's draft guidance documents represent recommendations and proposed approaches; they should not be treated as binding requirements until finalized.
Cybersecurity is a patient safety consideration for medical devices, not only an IT security matter. A cybersecurity failure that affects a medical device's performance, data integrity, or availability can result in harm to patients. FDA's approach to medical device cybersecurity reflects this understanding.
FDA's February 2026 Cybersecurity in Medical Devices guidance updates the previous 2023 guidance and addresses cybersecurity considerations for applicable cyber devices, as defined in Section 524B of the FD&C Act. For applicable cyber devices, FDA expects sponsors to submit a plan to monitor, identify, and address postmarket cybersecurity vulnerabilities, a software bill of materials (SBOM), and evidence that the device meets cybersecurity requirements. These are premarket submission requirements for applicable devices, not voluntary recommendations.
For medical device software development, cybersecurity should be addressed throughout the lifecycle, not addressed as a final testing step:
The specific cybersecurity requirements that apply depend on whether the device is an applicable cyber device under Section 524B, its connectivity characteristics, the clinical environment in which it is used, and the applicable regulatory pathway. A development partner should understand these distinctions and design security controls that are appropriate for the specific product.
A developer capable of building regulated medical device software is not simply a healthcare software developer who is familiar with HIPAA. Medical device software development requires a different set of engineering practices, documentation habits, process controls, and regulatory knowledge. Buyers should evaluate the following capabilities before selecting a development partner.
1. Experience with regulated medical device software
Ask whether the company has built SaMD, embedded medical device software, or other regulated medical device software that has reached the market. Relevant experience means working through the full lifecycle, including development, verification, testing, documentation, and release, not only prototype-level work.
2. Familiarity with IEC 62304 lifecycle processes
Ask how the team manages requirements, architectural design, unit implementation, verification, integration testing, system testing, and software maintenance. A team that understands IEC 62304 should be able to describe their process for each lifecycle activity and the documentation they produce.
3. Understanding of FDA expectations
Ask whether the team understands device software classification, intended use, and applicable documentation requirements for the submission type relevant to the buyer's product. The team should understand the difference between guidance and regulation, and between verification and validation.
4. Quality management system experience
Ask how the development team works within an ISO 13485-aligned quality environment. Specifically, ask how they handle design inputs and outputs, review records, change controls, and documentation in a way that supports the manufacturer's quality management system requirements.
5. Risk management capability
Ask how the team collaborates with the manufacturer's quality and regulatory functions on ISO 14971 risk management. Risk management should influence architecture, requirements, and testing decisions, not be completed as a document review after development is finished.
6. Verification and validation evidence
Request examples of traceability matrices, test plans, verification reports, and software validation documentation from past projects, with confidential information appropriately redacted. A team experienced in medical device software development will have these artifacts and should be able to explain how they connect to the development process.
7. Medical device cybersecurity experience
Ask how security risks are identified, documented, tested, and managed throughout development and maintenance. A team that addresses cybersecurity only at the testing phase is not applying it as a design consideration throughout the lifecycle.
8. Change and configuration management
Ask how software versions, component dependencies, changes, defect resolutions, and release decisions are documented and controlled. Configuration management is a core IEC 62304 process and a quality management system requirement. The answer should describe a systematic, documented approach, not an informal practice.
Buyer caution: A development company that claims to be "FDA compliant" or "IEC 62304 certified" without being able to describe its specific processes, documentation outputs, and evidence of past regulated projects is not demonstrating the capability those claims suggest. Request process documentation and redacted project examples rather than accepting general claims of compliance.
A proposal that promises "FDA-compliant software development" without defining processes, deliverables, and responsibilities does not give a buyer the information needed to evaluate whether the developer understands what they are committing to. A credible proposal should address the following elements:
Regulated medical software requires more than competent software engineering. It requires a development partner that understands the product's intended medical purpose, can reason about its regulatory classification, follows a documented lifecycle process aligned with IEC 62304, integrates risk management throughout development rather than at the documentation phase, produces evidence of verification and validation connected to requirements and risks, manages cybersecurity as a design consideration, and plans for ongoing maintenance and change management after the software is released.
The medical device manufacturer retains applicable regulatory responsibilities regardless of which development activities are outsourced. That includes regulatory strategy, quality management system oversight, supplier management, and responsibility for the accuracy and completeness of any premarket submission. A development partner can contribute expertise and deliverables, but it cannot take on the manufacturer's regulatory responsibilities. Buyers should understand that division before engaging any external development team.
The practical implication for outsourcing decisions: a development company's capability claims should be evaluated against specific process descriptions, documentation examples, and evidence of past regulated projects, not against general claims of FDA compliance or healthcare software experience. The questions in this article provide a starting point for that evaluation.
TechRadiant's directory of medical device software development companies provides a resource for evaluating development partners with regulated medical device software experience before shortlisting and due diligence.